Image LPS Stock # Description Model # Application EPA QTY Price
LCA071Z397 Cummins, Air-cooled, 20kW, 120/240V, 60 Hz, NG/LP, 75/83.3A, 3600 rpm, 100A circuit breaker, remote monitoring capability, 4A battery charger, 65 dB(A) rated sound-attenuated weather protective enclosure, alternator slip ring heater. NFPA 37 compliant. Cummins C20N6H Generator Set Emergency Stationary Standby US EPA 1 Call For Price
LCA071Z402 (COMBO)
Genset: Cummins, Air-cooled, 20kW, 120/240V, 60 Hz, NG/LP, 75/83.3A, 3600 rpm, 100A circuit breaker, remote monitoring capability, 4A battery charger, 65 dB(A) rated sound-attenuated weather protective enclosure, alternator slip ring heater. NFPA 37 compliant ATS: Cummins, RA series, 200A service entrance rated, NEMA 3R .
Cummins C20N6HC (Combo) Generator Set with 200A ATS Emergency Stationary Standby US EPA 1 Call For Price
LCA051Y417 Cummins, Quiet Connect Series, Liquid-cooled, 36.0kW, 120/240V, 1-Phase, 60 Hz, 150.0/150.0A, 1800 rpm, NG/LP single fuel - field configurable, 4 lead alternator, PCC1.1 two-wire start control, 175A circuit breaker, 6A battery charger, level 1 sound attenuated weather protective enclosure, coolant heater. Cummins C36N6 Spark-ignited Generator Set Emergency Stationary Standby US EPA Certified 1 Call For Price
LCA054F666 Cummins, Quiet Connect Series, Liquid-cooled, 60.0kW, 120/240V, 1-Phase, 60 Hz, 250.0/250.0A, 1800 rpm, NG/LP single fuel - field configurable, 8 lead alternator, PCC1.1 two-wire start control, 250A circuit breaker, 6A battery charger, block heater, level 1 sound-attenuated weather protective enclosure, 1000W coolant heater. Cummins C60N6 Spark-Ignited Generator Set Emergency Stationary Standby US EPA Certified 1 Call For Price
LCA051Y401 Cummins, Quiet Connect Series, Liquid-cooled, 30.0kW, 120/240V, 1-Phase, 60 Hz, 125.0/125.0A, 1800 rpm, NG/LP single fuel - field configurable, 4 lead alternator, PCC1.1 two-wire start control, 150A circuit breaker, 6A battery charger, level 1 sound attenuated weather protective enclosure, coolant heater. Cummins C30N6 Spark-Ignited Generator Set Emergency Stationary Standby US EPA Certified 1 Call For Price
LCA051Y419 Cummins, Quiet Connect Series, Liquid-cooled, 40.0kW, 120/240V, 1-Phase, 60 Hz, 166.7/166.A, 1800 rpm, NG/LP single fuel - field configurable, 4 lead alternator, PCC1.1 two-wire start control, 200A circuit breaker, 6A battery charger, level 1 sound attenuated weather protective enclosure, coolant heater. Cummins C40N6 Spark-Ignited Generator Set Emergency Stationary Standby US EPA Certified 1 Call For Price
LCA054F630 Cummins, Quiet Connect Series, Liquid-cooled, 50.0kW, 120/240V, 1-Phase, 60 Hz, 208.0/208.0A, 1800 rpm, NG/LP Single fuel - field configurable, 8 lead alternator, PCC1.1 two-wire start control, 250A circuit breaker, 6A battery charger, level 1 sound attenuated weather protective enclosure, 1000W coolant heater. Cummins C50N6 Spark-Ignited Generator Set Emergency Stationary Standby US EPA Certified 1 Call For Price