Volvo Penta Industrial Power Generation Systems in California
For commercial and municipal facilities, dependable backup and prime power are non-negotiable. Leddy Power delivers fully integrated industrial generator solutions—including Volvo Penta diesel packages and ASCO controls—for California businesses, schools, and farms. The installation teams here at Leddy Power are trained to provide a fully comprehensive service that includes selecting the proper engine for your needs and meeting compliance requirements, so that your power source is up to NFPA 110 emergency standards and California’s emission regulations.
Power Types: Standby vs Prime vs Continuous
Prime Power
When you don’t have access to a power grid, we will select a generator package that will reliably serve as your primary power. This is ideal for more remote sites.
F5 Series
Covering the 43–105 kW range via the F34 and F36 models, this engine family targets mid-range tractors and utility equipment that require more power than the F28 but do not necessitate the size and mass of the NEF series. Applicable configurations incorporate HI-eSCR2 aftertreatment: FPT's patented, maintenance-free SCR system that eliminates regeneration downtime.
Continuous Power
Runs unlimited hours to supply critical loads without utility support (rare in grid-connected facilities).
Sizing depends on the application. A hospital emergency switchgear might require 100% standby capacity per NFPA 110, while a remote manufacturing plant might use a prime-rated generator as the main power source. Leddy Power advises on the correct configuration for your use case.
Equipment & Compliance
Manual transfer equipment is appropriate when:
Engine Types
We at Leddy Power supply a myriad of brands from Volvo Penta to HIPOWER and more, appropriate for ~50kW small buildings all the way up to multi-MW systems for largescale projects.
Emissions
All diesel engines are Tier 4 Final compliant for NOx/PM, meeting California CARB and SCAQMD/BAAQMD rules. For cleaner sites, we also offer natural gas units.
Standards
All of our generators are certified to UL 2200. For related ATS, we adhere to UL 1008 and UL 891/1558 for all switchgear. We also ensure compliance with NFPA 110/NFPA 99 for all systems deemed critically essential.
Sound Attenuation
Weatherproof enclosures reduce noise below local ordinance limits. We consider proximity to neighbors (especially in dense LA/Orange County areas).
Integration
Automatic transfer switches, paralleling controls, and remote monitoring are included. We can also integrate generators into building management systems for automated notifications.
California Considerations

PSPS Preparedness
In high fire-risk zones (Napa, Santa Barbara, etc.), backup generators sized for resiliency are key. Leddy Power designs systems to power critical loads (e.g., water pumps, schools) during outages.

Regulations
California requires emissions permits for large diesels. We guide you through District approvals or help you opt for natural gas to avoid diesel restrictions.

Seismic Requirements
All generator pads and enclosures are anchored to meet California seismic criteria.
Whether you need a single 250kW standby generator or a bank of units for an industrial plant, we tailor the solution to site conditions and codes.
Installation Process
Site Survey & Load Calc
Our engineers assess your electrical load profile, utility service, and space.
Equipment Selection
We choose engine/generator sets (e.g. Volvo Penta 13L diesels) and enclosures to match the calculated load plus reserves.
Permitting
We are experts in complying with California's electrical, environmental, and structural permitting laws.
System Installation
All of our teams at Leddy Power are certified for technical installation and are ready to set up your generator, ATS, fuel system, and electrical interdependencies. If you’re using temporary rental backup generators, we can install quick-connect panels as well.
Testing & Training
Each system is run through a full load bank test for NFPA compliance, and we will ensure your staff is trained to operate the system safely.
- Full-Service Expert Installation
- Genuine FPT Industrial Power Generation
- Preventative Maintenance Programs
- 2-Year/ 2,000-Hr Standby Warranty
- 24/7 Emergency Service Support
Frequently Asked Questions
What’s the cost of a commercial generator system?
The cost of a commercial system can range from $20,000 to $200,000+, depending on power rating, enclosure, and options. Our quotes are comprehensive and account for the unit itself, installation, and commissioning.
How long does a generator last?
With proper maintenance, 20+ years. Key factors are usage hours and service frequency.
Do generators need annual testing?
Yes. To comply with NFPA 110, weekly exercises and annual load bank tests are required by the state. We are happy to create this schedule and document everything for your records.
What permits are required?
The permits most often required are electrical and structural, and air quality permits come into play for diesel engines. We will gladly assist with all of the necessary filings.
Our Blog
Running a Job Site in California? The HRFW 325-400 Is Why Serious Contractors Stop Worrying About the Generator
When a job site in California goes dark, everything stops. Cranes idle, compressors cut out, and the clock on your contract keeps running. Whether you’re managing a construction project in the Central Valley, powering a film production in the Mojave, or keeping a...
Tips to Help You Choose The Perfect Standby Generator for Your Home Needs
Power outages are an inconvenience for most households — but for some, they are a genuine emergency. Whether you rely on electrically powered medical equipment, work from home and cannot afford an unexpected loss of connectivity, or simply want to protect your home...
Reasons Behind Your Spark-Ignited Generator Failing to Start From Moorpark Experts
If your backup system refuses to fire up when you need it most, you’re likely searching for answers about a spark-ignited generator failing to start in Moorpark. Whether it’s a residential standby unit or a commercial backup system, a no-start condition can quickly...
GET IN TOUCH
Call us at (805) 552-4221 or Contact Us